Chapter Four · failure evidence

What Colloidal & Suspension Rheology got wrong, from 47 dissertations

The records document widespread experimental, modeling, and processing failures encountered across colloidal dispersions, complex pastes, and polymeric fluids. Practitioners frequently struggle with printable viscosity bounds in additive manufacturing, constitutive equation breakdowns in structured fluids, severe measurement artifacts in rheometry, and high resistance during mixing and flow. These records come from PhD theses at 17 institutions, 2021 to 2026. Each links to its thesis. They were extracted by language models reading the full text, so treat each as a lead to read, not a verdict.

Inkjet and direct-write printing fail when ink viscosity and yield stress fall outside operational limits

16 theses · 9 institutions

Formulations with insufficient viscosity or yield stress suffer from liquid spreading, poor shape fidelity post-deposition, and uncontrolled pore infiltration. Conversely, overly viscous, dilatant, or shear-thickening inks cause nozzle clogging, droplet formation failure, and tunneling through the surrounding matrix.

Tried and failed

semi-solid extrusion 3D printing applied to low-concentration single-component biopolymer hydrogels. Outcome: unstable. Reason: insufficient viscosity and low yield stress caused spreading and loss of shape fidelity post-deposition

Semi-solid extrusion-based 3D printing of biopolymer hydrogels and their applications in food · Iowa State

Tried and failed

pneumatic extrusion bioprinting applied to time-dependent viscous hydrogel precursor. Outcome: unstable. Reason: viscosity changed over time, causing bioink deposition rate per unit distance to continuously decrease

Development of physiologically representative multi-channel in vitro human skin tissue platforms for quantitative burn injury assessment · UT Austin

Tried and failed

vertical orientation fused deposition modeling printing applied to nanocomposite polymer blend filaments. Outcome: unstable. Reason: highly sensitive complex viscosity behavior during deposition prevented successful structural printing

Filament fabrication and fdm 3D printing of pla/biopbs-based composite materials for advanced sustainable manufacturing applications · Cranfield

Tried and failed

direct extrusion of undiluted clay paste applied to additive manufacturing of functional pastes. Reason: excessive paste viscosity prevented extrusion through the print nozzle

Printable, functional components with actuatable function and sensing, for CO2 uptake in reduced gravity environments · Imperial

Considered and rejected

Considered and rejected: Rejected using 3D inkjet printing (CeraPrinter X-Series) for membrane fabrication due to powder agglomeration and unstable colloidal ink rheology

Recovering materials from end-of-life lithium-ion batteries · Imperial

Considered and rejected

Considered and rejected: Rejected 70 wt% polymer formulations in ethyl acetate for 3D printing due to excessive viscosity exceeding the 10 Pa·s continuous printing threshold.

Photochemical 3D Printing of Prototype Medical Devices from Poly(Propylene Fumarate)-Based Copolyesters · DukeSpace

Considered and rejected

Considered and rejected: Rejected dropper-based droplet drying for traditional binder due to excessive viscosity clogging the dropper.

A Technical Study of Fish Collagen-Based Binder for Architectural Polychrome Painting in Jiangsu Province: History and Application · Penn

Considered and rejected

Considered and rejected: Rejected pure cyclohexane slip casting suspension for direct ink writing due to excessively low viscosity and dilatant behavior at high solid loadings (>55 vol%)

Near-Net Shaping and Additive Manufacturing of Ultra-High Temperature Ceramics via Colloidal Processing · Virginia Tech

Lost to a baseline

Inkjet-printed PEDOT:PSS on nitrocellulose exhibited ~6x lower ON current in modulus compared to dispense-printed PEDOT:PSS due to low-viscosity ink dispersion in pores.

A printable Organic Electrochemical Transistor on paper for biochemical sensing · IRIS - POLITO - prod

Considered and rejected

Considered and rejected: Rejected inkjet/jetting processes for polymer solutions because high dynamic viscosity (Z ~ 0.05) prevents droplet formation in the viscous dissipation regime.

Sensor-based Characterization and Control of Additive Biomanufacturing Processes · Virginia Tech

Considered and rejected

Considered and rejected: Viscosity ratios eta_ink >> eta_matrix were rejected because the ink tunneled through the matrix during extrusion rather than forming cohesive spherical nodes

Embedded 3D Printing of Polymeric and Ceramic Lattices · Harvard

Considered and rejected

Considered and rejected: Commercial inkjet printers without electrostatic field, rejected due to poor handling of high-viscosity inks and microscale cracking.

Real-time monitoring of neuronal cells through electrohydrodynamic patterning of flexible graphene microelectrodes · Iowa State

Considered and rejected

Considered and rejected: Rejected inkjet printing of P(VDF-TrFE) using Dimatix printer due to strict 10–12 mPas ink viscosity constraints not met by dissolution process.

Life cycle monitoring of composite aircraft components with structural health monitoring technologies · Imperial

Considered and rejected

Considered and rejected: Rejected standard inkjet printing because it requires pressure and is limited to low-viscosity materials (5 to 20 mPa·s).

The E-jet printing of organic inks on organic substrates · Iowa State

Considered and rejected

Considered and rejected: Rejected matching ink viscosity across particle sizes in favor of matching ink solids content (50 wt%), because shear-thinning profiles converged at high shear rates (>10 s⁻¹).

Smaller is better: reducing silver nanoparticle size without excess ligands enhances conductivity and flexibility in printed thin films · Iowa State

Considered and rejected

Considered and rejected: Rejected using pure cell inks without microparticles for STEP due to their lower storage modulus, loss modulus, yield stress, and apparent viscosity.

Programmable Assembly of Genetically Engineered Human Tissues · Harvard

Standard constitutive rheology models fail to capture microstructural changes and non-Newtonian behavior

8 theses · 4 institutions

Classical models such as Carreau, Casson, and Herschel-Bulkley break down when fluid microstructures are altered by aeration, incomplete polymer hydration, or shear-induced deformation. These constitutive equations generate unphysical zero-shear viscosities, non-monotonic fitting errors, and unstable flow index predictions under low shear rates.

Tried and failed

Empirical Carreau rheology model parameter fitting applied to incompletely hydrated polymer solutions. Reason: Poor hydration and microgels caused non-monotonic, scattered low-shear viscosity data that violated model assumptions

Database, Spreadsheet, and Models for Polymer Chemical Enhanced Oil Recovery · UT Austin

Considered and rejected

Considered and rejected: Rejected arbitrary viscosity partitioning in Burgers transient rheological models (e.g. fixing eta_KM / eta_M = 1/10), because it lacks experimental physical basis and cannot be generalized across differing forcing timescales.

Fire and ice: investigating links between mantle dynamics and ice sheet stability · Imperial

Tried and failed

Casson rheological model fitting applied to aerated complex fluid shear viscosity. Outcome: did not generalise. Reason: standard suspension constitutive model failed across tested shear rates once micro-aeration altered the fluid microstructure

Oral processing of micro-aerated chocolates: a computational mechanics, rheological and tribological study · Imperial

Tried and failed

empirical droplet size scaling models applied to high-viscosity fluid atomization. Outcome: did not generalise. Reason: shear-thinning non-Newtonian behavior invalidated constant-viscosity assumptions

Airblast atomization : the effect of linear scale on the mean drop size · Cranfield

Tried and failed

Herschel-Bulkley rheological model applied to low shear rate multiphase flow simulation. Reason: Predicts infinite viscosity at near-zero shear rates, causing unrealistic velocity profiles and transport errors

Rheological characterization of complex drilling fluid and the effects on drilling hydraulics · UT Austin

Tried and failed

Herschel-Bulkley model fitting at low shear rates applied to colloidal hydrogel rheology data. Outcome: unstable. Reason: low shear rate stress instabilities produced inconsistent and unphysical flow index values (>1)

Synthetic, rheological, and morphological control of one-dimensional CdS and Sb₂S₃ nanomaterials · UT Austin

Considered and rejected

Considered and rejected: Rejected assuming clusters are strictly rigid under flow in the viscosity model, introducing cluster flexibility/rigidity attenuation scaling with cluster size.

Protein-protein interactions and rheological properties of monoclonal antibodies at high concentration · UT Austin

Considered and rejected

Considered and rejected: Rejected using Cross, Sisko, or Carreau-Yasuda models due to excessive parameters not broadly applicable across disparate colloidal regimes

Predicting the Flow Rate and Extensional Behavior of Colloidal Dispersions for 3D Printing Applications · Texas Tech

Elevated suspension viscosity impairs fluid mixing, coating uniformity, and continuous handling

7 theses · 5 institutions

Highly viscous and shear-thickening composite suspensions generate excessive mechanical energy dissipation and impede secondary emulsification and polymer dissolution. High resistance to flow also leads to inhomogeneous liquid distribution in binders, irregular coating profiles, and severe dispersion difficulties.

Considered and rejected

Considered and rejected: Rejected continuous flow mode for the semi-solid Na-S flow battery in favor of intermittent aliquot flow due to high suspension viscosity causing mechanical energy dissipation.

Electrochemical Flow System for Li-Ion Battery Recycling and Energy Storage · Virginia Tech

Considered and rejected

Considered and rejected: Rejected liquid sucrose aqueous solutions as binders because high viscosity led to inhomogeneous liquid distribution and excessively delayed disintegration times

Novel drug-loaded paper tablets for improved oral drug delivery Neuartige Papiertabletten mit Wirkstoffbeladung für verbesserte orale Arzneimittelverabreichung · open_UMR Marburg DSpace 10.0

Considered and rejected

Considered and rejected: Rejected protein concentrations above 2% w/v for microneedle coating due to excessive viscosity causing irregular coating.

Metal-Organic Frameworks for Long-term Vaccine Storage · Georgia Tech

Considered and rejected

Considered and rejected: Rejected primary emulsion formulations with 1.5%–4% psyllium husk because high viscosity hindered secondary emulsification mixing.

Ultrasound-Assisted Novel Double Emulsion Containing Grape Pomace Polyphenols as a Delivery System to Encapsulate Vitamin E and Omega-3 for Food and Dietary Supplement Applications · Carleton University Institutional Repository

Considered and rejected

Considered and rejected: Rejected testing polymer concentrations above 11–16 wt% in cloud point and dissolution tests due to rapid solution viscosity increase preventing adequate mixing

Solvent-Enabled Molecular Recycling of Polyolefins · DSpace at SUNY Buffalo

Considered and rejected

Considered and rejected: Direct mixing of concentrated CNC/CNF gels into polymer solutions rejected due to poor dispersion and lower gel modulus than composite reverse dialysis

Rheological Characterization of Cellulose Nanomaterials for Quality Control and Processing · Georgia Tech

Considered and rejected

Considered and rejected: Rejected PAN/LDH composite suspensions with higher LDH contents (≥12.6 wt.%) due to shear-thickening behavior, particle aggregation, and increased suspension viscosity.

Nanostructured Adsorbents for Selective Lithium Recovery: Mechanisms, Fabrication, Performance Evaluation, and Applications in Desalination · Virginia Tech

Rheometrical characterization suffers from measurement artifacts, wall slip, and phase separation

5 theses · 4 institutions

Smooth test geometries induce significant wall slip and sample ejection at elevated shear rates, leading to severe underestimation of viscosity. In addition, lack of solvent density matching induces gravitational sedimentation while discontinuous shear thickening produces extreme stress fluctuations that disrupt steady-state rheometry.

Tried and failed

non-standard polymer dissolution and mixing protocols applied to polymer rheology and viscosity characterization. Reason: incorrect sample preparation caused severe artificial overestimation of low-shear viscosity

Database, Spreadsheet, and Models for Polymer Chemical Enhanced Oil Recovery · UT Austin

Tried and failed

suspension characterization without solvent density matching applied to dilute colloidal gel systems. Outcome: unstable. Reason: gravitational sedimentation caused sample failure at low volume fractions without precise solvent density matching

Microscopic characterization of macroscopic colloidal gel rheology · MIT

Tried and failed

strain-controlled rheometry applied to discontinuous shear thickening colloidal suspensions. Outcome: unstable. Reason: extreme stress fluctuations and critical shear rate variability prevented capturing controlled states across the discontinuity

Microscopic characterization of macroscopic colloidal gel rheology · MIT

Tried and failed

Environmental and mechanical conditioning of yield-stress fluids applied to concentrated colloidal dispersions. Reason: Treatments failed to reliably recreate cohesive structural failure or control rheological breakdown

Extrusion Printing of Carbon Nanotube Inks, from Rheology to Electronics · MIT

Tried and failed

rotational rheometry with smooth plate geometry applied to yield-stress capillary suspension inks. Outcome: unstable. Reason: smooth geometries induced severe wall slip and sample ejection at high shear rates, underestimating viscosity

Direct ink writing of aqueous electrochemical energy storage devices · Imperial

Lost to a baseline

Liquid handler viscosity determination underestimated capillary viscometer measurements by ~7 cSt offset due to measurement shear thinning or pressure conversion models.

Synthesis and application of novel hyperbranched polymers · University of Nottingham Repository

Colloidal stability and redispersion predictions fail due to shifting sedimentation regimes and agglomeration

2 theses · 2 institutions

Extrapolating long-term suspension stability from initial settling rates fails because sedimentation mechanisms transition through different physical regimes over time. Furthermore, conventional dewatering treatments like freeze drying and filter pressing cause severe particle agglomeration and impurity retention that prevent redispersion.

Tried and failed

extrapolating long-term stability from initial settling rate applied to colloidal suspension stability estimation. Outcome: did not generalise. Reason: sedimentation mechanisms shift across different regimes over time

Investigation on the performance of nanofluids due to preparation effects and operational conditions. · Cranfield

Lost to a baseline

Filter-pressing and freeze drying failed to match ultrasonic dewatering for redispersion ease; filter-pressed samples retained impurities/residues and freeze-dried samples exhibited severe agglomeration that precluded optical and SEM image analysis even after 5 minutes of mixing.

Dewatering of Cellulose Nanomaterials using Ultrasound · Georgia Tech

Left open by the authors

Problems the authors named and did not get to.

Left open

Design ionic liquid cations with enhanced Li+ chelating affinity, reduced viscosity, and high chemical stability for lithium-bromine flow batteries. Blocker: Requires chemical synthesis, wet-lab validation, and electrochemical testing facilities

Learning the Electrochemistry of Degradation and Safety in Graphite Porous Electrodes for Lithium-ion Batteries · MIT

Left open

Apply colloidal synthesis to fabricate MoSe2-carbon heterostructures and evaluate their cycling stability in batteries. Blocker: Requires wet-lab chemical synthesis and battery testing apparatus

Liquid phase synthesis of atomically thin MoSe2 and their applications in energy conversion and storage · Imperial

Left open

Extend bulk polymer rheology models to predict in-situ apparent viscosity within porous media. Blocker: Requires porous media coreflood experimental data and rheological laboratory measurements for validation.

Exploring mobility-related challenges in enhanced oil recovery : advanced analytical solutions for polymer rheology, injectivity, induced fracturing, and low-tension-gas in tight o · UT Austin

Left open

Incorporate additive manufacturing microstructural heterogeneities into dynamic failure models to predict spall strength and shock dispersion. Blocker: None

The Effects of Controlled Porosity on the Dynamic Compression and Tensile Failure Strength of Additively Manufactured 316L Stainless Steel · Georgia Tech

Left open

Measure physical properties and viscosity changes when incorporating tardigrade disordered proteins into pharmaceutical formulations. Blocker: Requires a wet lab and rheological measurement apparatus to formulate and test protein solutions

Intrinsically Disordered Proteins & Regions in Viruses and Possibly Pharmaceuticals · UT Austin

Left open

Systematically vary polymer cross-linker density at fixed particle volume fraction to test the polymer-reinforced aggregate hypothesis. Blocker: Requires a wet lab, chemical synthesis of cross-linked polymers/silica dispersions, and a strain-controlled rheometer.

Mechanical Hysteresis of Fumed Silica Dispersions · Harvard

Left open

Perform rheological testing on pAA-lactose-C12 and pAA-lactose-C16 polymers to verify shear thinning and viscosity properties. Blocker: Requires physical synthesized polymer samples and specialized rheology measurement equipment/services (Formulaction).

Surface-Active Synthetic Glycocalyx and Lipid Layer Analogs for the Treatment of Dry Eye Disease · Cornell

Left open

Evaluate the effects of polymer molar mass on dense paste mixing behavior using viscosity-matched binders across different viscosities in RAM. Blocker: Requires a physical chemistry/materials wet lab, Resonant Acoustic Mixer (RAM), and formulation chemicals.

Formulation and Process Considerations for the Manufacturing of Dense Pastes · Georgia Tech

Left open

Investigate scalings of normal stress differences, complex modulus, and friction coefficients near the frictional shear jamming critical point. Blocker: Requires a physical rheometer and custom piezoelectric transducer apparatus for dense colloidal suspensions

UNDERSTANDING AND TUNING THE RHEOLOGY OF DENSE SUSPENSIONS VIA ITS MICROSTRUCTURE · Cornell

Left open

Investigate the breakdown of the quasi-static assumption and measure the effects of fluid viscosity on fractal landscape dynamics. Blocker: Requires experimental laboratory apparatus and physical soft jammed emulsion systems to vary strain rate and fluid viscosity.

A fractal landscape dynamics approach to understanding particle motion in soft jammed materials · Penn

Checking a claim in this area?

We can run the same search on any method or claim. If nothing turns up, we will say so, and that proves nothing on its own.